Commission Regulation (EC) No 333/2007 of 28 March 2007 laying down the methods o... (32007R0333)
Commission Regulation (EC) No 333/2007 of 28 March 2007 laying down the methods o... (32007R0333)
COMMISSION REGULATION
(EC) No 333/2007
of 28 March 2007
laying down the methods of sampling and analysis for the official control of the levels of lead, cadmium, mercury, inorganic tin, 3-MCPD and benzo(a)pyrene in foodstuffs
(Text with EEA relevance)
Article 1
Article 2
Article 3
ANNEX
PART A
DEFINITIONS
PART B
SAMPLING METHODS
B.1. GENERAL PROVISIONS
B.1.1. Personnel
B.1.2. Material to be sampled
B.1.3. Precautions to be taken
B.1.4. Incremental samples
B.1.5. Preparation of the aggregate sample
B.1.6. Samples for enforcement, defence and referee purposes
B.1.7. Packaging and transmission of samples
B.1.8. Sealing and labelling of samples
B.2. SAMPLING PLANS
|
Lot weight (ton) |
Weight or number of sublots |
|
≥ 1 500 |
500 tonnes |
|
> 300 and < 1 500 |
3 sublots |
|
≥ 100 and ≤ 300 |
100 tonnes |
|
< 100 |
— |
|
Lot weight (ton) |
Weight or number of sublots |
|
≥ 15 |
15 to 30 tonnes |
|
< 15 |
— |
|
Weight or volume of lot/sublot (in kg or litre) |
Minimum number of incremental samples to be taken |
|
< 50 |
3 |
|
≥ 50 and ≤ 500 |
5 |
|
> 500 |
10 |
|
Number of packages or units in the lot/sublot |
Number of packages or units to be taken |
|
≤ 25 |
at least one package or unit |
|
26 to 100 |
about 5 %, at least two packages or units |
|
> 100 |
about 5 %, at maximum 10 packages or units |
B.3. SAMPLING AT RETAIL STAGE
PART C
SAMPLE PREPARATION AND ANALYSIS
C.1. LABORATORY QUALITY STANDARDS
C.2. SAMPLE PREPARATION
C.2.1. Precautions and general considerations
C.2.2. Specific sample preparation procedures
C.2.2.1. Specific procedures for lead, cadmium, mercury and inorganic tin
C.2.2.2. Specific procedures for benzo(a)pyrene
C.2.3. Treatment of the sample as received in the laboratory
C.2.4. Samples for enforcement, defence and referee purposes
C.3. METHODS OF ANALYSIS
C.3.1. Definitions
C.3.2. General requirements
C.3.3. Specific requirements
C.3.3.1. Performance criteria
|
Parameter |
Value/Comment |
|
Applicability |
Foods specified in Regulation (EC) No 1881/2006 |
|
LOD |
For inorganic tin less than 5 mg/kg. For other elements less than one tenth of the maximum level in Regulation (EC) No 1881/2006, except if the maximum level for lead is less than 100 μg/kg. For the latter, less than one fifth of the maximum level |
|
LOQ |
For inorganic tin less than 10 mg/kg. For other elements less than one fifth of the maximum level in Regulation (EC) No 1881/2006, except if the maximum level for lead is less than 100 μg/kg. For the latter, less than two fifth of the maximum level |
|
Precision |
HORRATr or HORRATR values of less than 2 |
|
Recovery |
The provisions of point D.1.2. apply |
|
Specificity |
Free from matrix or spectral interferences |
|
Criterion |
Recommended Value |
Concentration |
|
Field blanks |
Less than the LOD |
— |
|
Recovery |
75 to 110 % |
all |
|
LOD |
5 μg/kg (or less) on a dry matter basis |
|
|
LOQ |
10 μg/kg (or less) on a dry matter basis |
— |
|
Precision |
< 4 μg/kg |
20 μg/kg |
|
< 6 μg/kg |
30 μg/kg |
|
|
< 7 μg/kg |
40 μg/kg |
|
|
< 8 μg/kg |
50 μg/kg |
|
|
< 15 μg/kg |
100 μg/kg |
|
Parameter |
Value/Comment |
|
Applicability |
Foods specified in Regulation (EC) No 1881/2006 |
|
LOD |
Less than 0,3 μg/kg |
|
LOQ |
Less than 0,9 μg/kg |
|
Precision |
HORRATr or HORRATR values of less than 2 |
|
Recovery |
50 to 120 % |
|
Specificity |
Free from matrix or spectral interferences, verification of positive detection |
C.3.3.2. ‘Fitness-for-purpose’ approach
|
C (μg/kg) |
α |
|
≤ 50 |
0,2 |
|
51 to 500 |
0,18 |
|
501 to 1 000 |
0,15 |
|
1 001 to 10 000 |
0,12 |
|
> 10 000 |
0,1 |